other

三叶偏振控制器

  • Low insertion loss
  • Wide wavelength range
  • Easy disassemble,self-replacement,winding fiber
  • 产品详细信息


The mechanical three-ring polarization controller

 

Product description

 

The mechanical three-ring polarization control is based on the principle of Birefringence produced by optical fiber under external force. The three rings are equivalent to λ/4, λ/2 and λ/4 wave plates, respectively. The light waves passing through λ/4 wave plates are converted into linearly polarized light, and the polarization direction is adjusted by/2 wave plates. Finally, the polarization state of linearly polarized light is changed into arbitrary polarization state by/4 wave plates. The delay effect produced by the birefringence effect is mainly determined by the cladding radius of the fiber, the fiber ring radius and the wavelength of the light, the adjusted polarization state can cover the entire poincare sphere.   


Application area

 


  • Single mode to polarization-maitaining fiebr
  • Polarization-related loss measurement.
  • Polarization-sensitive device application
  • Fiber lasers
  • Fiber interferometers


 

Product structure diagram

 偏振控制器


Schematic diagram of polarization controller

 偏振控制器

 

Relationship between single-loop delay and wavelength , number of loops in polarization controller.(Test unit: fiber loop diameter 40mm, fiber cladding diameter 900µm)

For example: Polarization controller fiebr loop fixed diameter of 40 mm, the cladding diameter of 900µm of tight-sheathed fiber around in the ghost.

When λ=1550nm , and loop number =1 , the ring is equivalent toλ/2 wave plate.

When λ=1550nm , and loop number =3, the ring is equivalent to 3λ/2 wave plate


想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
光话机 光话机/稳定光源一体机、光电话、光纤电话机
全双工数字语音通信功能 话音清晰,背景噪声小 提供在线显示及呼叫功能 大屏幕显示 电池电压提示
多通道高速光功率计模块 多通道高速光功率计模块
外形小巧、尤其适于系统集成及二次开发; 启动快速、测量精度高 大动态测试 可选光功率探测范围 可选1~4通道光功率计 丰富的通信指令集及demo软件支持
多通道高速光功率计模块 多通道高速光功率计模块
3.5英寸彩屏显示 90dB的动态范围 最大支持45个校准波长 阈值设置通过/未通过告警功能 波长自动识别功能 PMAX/PMin  实时测试 频率光的检测功能 提供实时数据读取功能,方便嵌入系统应用 可视故障定仪功能 存储数据1000条
100G CFP Module 100G CFP2 LR4 Dual Rate 10km Module
Features Supports multi-rate (100GE and OTU4); from 103.1Gb/s to 111.8Gb/s aggregate; Up to 10km transmission on SMF; LANWDM laser and PIN receiver with SOA; High speed I/O electrical interface (CAUI-4); MDIO interface with integrated Digital Diagnostic CFP2 MSA package with duplex LC connector; Single +3.3V power supply; Maximum power consumption 12W; Operating case temperature: 0 to +70 °C; Complies with IEEE802.3ba and ITU-T G.959.1; Complies with EU Directive 2015/863/EU; Application 100GBASE-LR4
4×4矩阵光开关切换设备 4×4矩阵光开关切换设备
4X4全通矩阵光开关切换 具有插入损耗小,切换速度快等特点 采用LCD显示屏,非常直观的显示光路状态,方便用户的操作。 可通过面板按键和串口指令两种方式进行光路切换设置。并可通过串口指令锁定按键操作
100G QSFP28 to 2x 50G QSFP28 AOC cable 100G QSFP28 to 2x 50G QSFP28 AOC Transceiver
Features 4 channels full-duplex transceiver modules Transmission data rate up to 28Gbps per channel Support 40GE and 56G FDR data rate 4 channels 850nm VCSEL array 4 channels PIN photo detector array Internal CDR circuits on both receiver and transmitter channels Support CDR bypass Low power consumption: QSFP28- 100G < 2.5W and QSFP28-50G
4G/5G 前传无源波分复用器 4G/5G 前传无源波分复用器
为满足数据流量的高速增长需求,运营商需不断地增加基站数量。传统的建站方式需要新建机房、购置设备及相关配套器件、投入人力等,周期长、投资与运维成本高。 为避免传统建站方式带来的缺点,运营商逐渐采用将多个BBU(Base Band Unit,基带处理单元)集中放置的方式。这种建站方式降低了机房租金投入、设备成本投入、人力投入等,使得工期大大缩减、投资运维成本大幅降低。但这种方式对光纤资源需求较大。若光纤资源匮乏或无管道资源,则较难实施。 瑞东光电公司的基站拉远光纤扩容系统,提供了一种既可实现BBU集中放置,又能大大减少光纤需求的建网方案。在光纤扩容系统中,通过在BBU和RRU上使用配套的彩光模块,提供不同波长的业务信号。将承载各个波长业务信号的光纤,分别连接到BBU侧和RRU侧的光纤扩展器。两侧的光纤扩展器将不同波长的信号通过线路侧的一条光纤进行传输,从而节省大量的光纤资源。
16路 双纤双向 C41-C56 DWDM 波分复用设备 (4联LC适配器) 16路 双纤双向 C41-C56 DWDM 波分复用设备 (4联LC适配器)
IL<3.5dB , 100GHZ DWDM MUX DEMUX Multiplexing of 16 Channels over a Dark Fiber Network Fully Compatible with All ITU-T 1G/10G/25G/40G/100G DWDM Optics Passive devices, No Power No Cooling Required Support Metro, Regional and Long Haul DWDM Networks
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系